CVE-2017-6015Date: (C)2018-05-14   (M)2023-12-22


Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.

CVSS Score and Metrics +CVSS Score and Metrics -

CVSS V3 Severity:CVSS V2 Severity:
CVSS Score : 7.8CVSS Score : 7.2
Exploit Score: 1.8Exploit Score: 3.9
Impact Score: 5.9Impact Score: 10.0
 
CVSS V3 Metrics:CVSS V2 Metrics:
Attack Vector: LOCALAccess Vector: LOCAL
Attack Complexity: LOWAccess Complexity: LOW
Privileges Required: LOWAuthentication: NONE
User Interaction: NONEConfidentiality: COMPLETE
Scope: UNCHANGEDIntegrity: COMPLETE
Confidentiality: HIGHAvailability: COMPLETE
Integrity: HIGH 
Availability: HIGH 
  
Reference:
BID-96996
https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02
https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382

CWE    1
CWE-74