CVE-2018-0088Date: (C)2018-01-22   (M)2023-12-22


A vulnerability in one of the diagnostic test CLI commands on Cisco Industrial Ethernet 4010 Series Switches running Cisco IOS Software could allow an authenticated, local attacker to impact the stability of the device. This could result in arbitrary code execution or a denial of service (DoS) condition. The attacker has to have valid user credentials at privilege level 15. The vulnerability is due to a diagnostic test CLI command that allows the attacker to write to the device memory. An attacker could exploit this vulnerability by authenticating to the targeted device and issuing a specific diagnostic test command at the CLI. An exploit could allow the attacker to overwrite system memory locations, which could have a negative impact on the stability of the device. Cisco Bug IDs: CSCvf71150.

CVSS Score and Metrics +CVSS Score and Metrics -

CVSS V3 Severity:CVSS V2 Severity:
CVSS Score : 6.7CVSS Score : 7.2
Exploit Score: 0.8Exploit Score: 3.9
Impact Score: 5.9Impact Score: 10.0
 
CVSS V3 Metrics:CVSS V2 Metrics:
Attack Vector: LOCALAccess Vector: LOCAL
Attack Complexity: LOWAccess Complexity: LOW
Privileges Required: HIGHAuthentication: NONE
User Interaction: NONEConfidentiality: COMPLETE
Scope: UNCHANGEDIntegrity: COMPLETE
Confidentiality: HIGHAvailability: COMPLETE
Integrity: HIGH 
Availability: HIGH 
  
Reference:
SECTRACK-1040240
https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-iess

CWE    1
CWE-732

© SecPod Technologies