CVE-2019-10979Date: (C)2019-07-02   (M)2023-12-22


SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password.

CVSS Score and Metrics +CVSS Score and Metrics -

CVSS V3 Severity:CVSS V2 Severity:
CVSS Score : 9.8CVSS Score : 7.5
Exploit Score: 3.9Exploit Score: 10.0
Impact Score: 5.9Impact Score: 6.4
 
CVSS V3 Metrics:CVSS V2 Metrics:
Attack Vector: NETWORKAccess Vector: NETWORK
Attack Complexity: LOWAccess Complexity: LOW
Privileges Required: NONEAuthentication: NONE
User Interaction: NONEConfidentiality: PARTIAL
Scope: UNCHANGEDIntegrity: PARTIAL
Confidentiality: HIGHAvailability: PARTIAL
Integrity: HIGH 
Availability: HIGH 
  
Reference:
BID-108924
https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories
https://www.us-cert.gov/ics/advisories/icsa-19-178-04

CWE    1
CWE-798