CVE-2019-13924Date: (C)2020-02-17   (M)2023-12-22


A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.

CVSS Score and Metrics +CVSS Score and Metrics -

CVSS V3 Severity:CVSS V2 Severity:
CVSS Score : 5.4CVSS Score : 4.3
Exploit Score: 2.8Exploit Score: 8.6
Impact Score: 2.5Impact Score: 2.9
 
CVSS V3 Metrics:CVSS V2 Metrics:
Attack Vector: NETWORKAccess Vector: NETWORK
Attack Complexity: LOWAccess Complexity: MEDIUM
Privileges Required: NONEAuthentication: NONE
User Interaction: REQUIREDConfidentiality: NONE
Scope: UNCHANGEDIntegrity: PARTIAL
Confidentiality: LOWAvailability: NONE
Integrity: LOW 
Availability: NONE 
  
Reference:
https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf
https://www.us-cert.gov/ics/advisories/icsa-20-042-07

CWE    1
CWE-693

© SecPod Technologies