CVE-2021-33533Date: (C)2021-06-28   (M)2023-12-22


In Weidmueller Industrial WLAN devices in multiple versions an exploitable command injection vulnerability exists in the iw_webs functionality. A specially crafted iw_serverip parameter can cause user input to be reflected in a subsequent iw_system call, resulting in remote control over the device. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.

CVSS Score and Metrics +CVSS Score and Metrics -

CVSS V3 Severity:CVSS V2 Severity:
CVSS Score : 8.8CVSS Score : 9.0
Exploit Score: 2.8Exploit Score: 8.0
Impact Score: 5.9Impact Score: 10.0
 
CVSS V3 Metrics:CVSS V2 Metrics:
Attack Vector: NETWORKAccess Vector: NETWORK
Attack Complexity: LOWAccess Complexity: LOW
Privileges Required: LOWAuthentication: SINGLE
User Interaction: NONEConfidentiality: COMPLETE
Scope: UNCHANGEDIntegrity: COMPLETE
Confidentiality: HIGHAvailability: COMPLETE
Integrity: HIGH 
Availability: HIGH 
  
Reference:
https://cert.vde.com/en-us/advisories/vde-2021-026

CWE    1
CWE-78

© SecPod Technologies