An issue was discovered in the Ascensia Contour NEXT ONE application for Android before 2019-01-15. It has a statically coded initialization vector. Extraction of the initialization vector is necessary for deciphering communications between this application and the backend server. This, in combination with retrieving any user's encrypted data from the Ascensia cloud through another vulnerability, ...

An XML External Entity injection (XXE) vulnerability exists in Zoho ManageEngine Network Configuration Manager and OpManager before 12.3.214 via the RequestXML parameter in a /devices/ProcessRequest.do GET request. For example, the attacker can trigger the transmission of local files to an arbitrary remote FTP server.

In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports resulting in memory consumption that could lead to a partial or complete denial-of-service condition to the affected services.

NUUO CMS All versions 3.3 and prior the web server application allows injection of arbitrary SQL characters, which can be used to inject SQL into an executing statement and allow arbitrary code execution.

VT-Designer Version 2.1.7.31 is vulnerable by the program reading the contents of a file (which is already in memory) into another heap-based buffer, which may cause the program to crash or allow remote code execution.

Medtronic CareLink 2090 Programmer CareLink 9790 Programmer 29901 Encore Programmer, all versions, The affected products do not encrypt or do not sufficiently encrypt the following sensitive information while at rest PII and PHI.

Tridium Niagara Enterprise Security 2.3u1, all versions prior to 2.3.118.6, Niagara AX 3.8u4, all versions prior to 3.8.401.1, Niagara 4.4u2, all versions prior to 4.4.93.40.2, and Niagara 4.6, all versions prior to 4.6.96.28.4 a cross-site scripting vulnerability has been identified that may allow a remote attacker to inject code to some web pages affecting confidentiality.

LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution.

VT-Designer Version 2.1.7.31 is vulnerable by the program populating objects with user supplied input via a file without first checking for validity, allowing attacker supplied input to be written to known memory locations. This may cause the program to crash or allow remote code execution.

LCDS Laquis SCADA prior to version 4.1.0.4150 allows execution of script code by opening a specially crafted report format file. This may allow remote code execution, data exfiltration, or cause a system crash.