CVE-2017-9857Date: (C)2017-08-09   (M)2024-04-19


An issue was discovered in SMA Solar Technology products. The SMAdata2+ communication protocol does not properly use authentication with encryption: it is vulnerable to man in the middle, packet injection, and replay attacks. Any setting change, authentication packet, scouting packet, etc. can be replayed, injected, or used for a man in the middle session. All functionalities available in Sunny Explorer can effectively be done from anywhere within the network as long as an attacker gets the packet setup correctly. This includes the authentication process for all (including hidden) access levels and the changing of settings in accordance with the gained access rights. Furthermore, because the SMAdata2+ communication channel is unencrypted, an attacker capable of understanding the protocol can eavesdrop on communications. NOTE: the vendor's position is that authentication with encryption is not required on an isolated subnetwork. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

CVSS Score and Metrics +CVSS Score and Metrics -

CVSS V3 Severity:CVSS V2 Severity:
CVSS Score : 8.1CVSS Score : 4.3
Exploit Score: 2.2Exploit Score: 8.6
Impact Score: 5.9Impact Score: 2.9
 
CVSS V3 Metrics:CVSS V2 Metrics:
Attack Vector: NETWORKAccess Vector: NETWORK
Attack Complexity: HIGHAccess Complexity: MEDIUM
Privileges Required: NONEAuthentication: NONE
User Interaction: NONEConfidentiality: PARTIAL
Scope: UNCHANGEDIntegrity: NONE
Confidentiality: HIGHAvailability: NONE
Integrity: HIGH 
Availability: HIGH 
  
Reference:
http://www.sma.de/en/statement-on-cyber-security.html
http://www.sma.de/fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1732_07.pdf
https://horusscenario.com/CVE-information/

CWE    1
CWE-287