CVE
view JSON

CVE-2017-9964Date: (C)2018-01-02   (M)2023-12-22


A Path Traversal issue was discovered in Schneider Electric Pelco VideoXpert Enterprise all versions prior to 2.1. By sniffing communications, an unauthorized person can execute a directory traversal attack resulting in authentication bypass or session hijack.

CVSS Score and Metrics +CVSS Score and Metrics -

CVSS V3 Severity:CVSS V2 Severity:
CVSS Score : 6.9CVSS Score : 5.8
Exploit Score: 1.6Exploit Score: 8.6
Impact Score: 4.7Impact Score: 4.9
 
CVSS V3 Metrics:CVSS V2 Metrics:
Attack Vector: NETWORKAccess Vector: NETWORK
Attack Complexity: HIGHAccess Complexity: MEDIUM
Privileges Required: NONEAuthentication: NONE
User Interaction: REQUIREDConfidentiality: PARTIAL
Scope: CHANGEDIntegrity: PARTIAL
Confidentiality: LOWAvailability: NONE
Integrity: HIGH 
Availability: NONE 
  
Reference:
BID-102338
https://ics-cert.us-cert.gov/advisories/ICSA-17-355-02
https://www.schneider-electric.com/en/download/document/SEVD-2017-339-01/

CWE    1
CWE-22

© SecPod Technologies