CVE-2018-7268 | Date: (C)2018-05-22 (M)2023-12-22 |
MagniComp SysInfo before 10-H81, as shipped with BMC BladeLogic Automation and other products, contains an information exposure vulnerability in which a local unprivileged user is able to read any root (uid 0) owned file on the system, regardless of the file permissions. Confidential information such as password hashes (/etc/shadow) or other secrets (such as log files or private keys) can be leaked to the attacker. The vulnerability has a confidentiality impact, but has no direct impact on system integrity or availability.
CVSS Score and Metrics +CVSS Score and Metrics -CVSS V3 Severity: | CVSS V2 Severity: |
CVSS Score : 5.5 | CVSS Score : 4.9 |
Exploit Score: 1.8 | Exploit Score: 3.9 |
Impact Score: 3.6 | Impact Score: 6.9 |
|
CVSS V3 Metrics: | CVSS V2 Metrics: |
Attack Vector: LOCAL | Access Vector: LOCAL |
Attack Complexity: LOW | Access Complexity: LOW |
Privileges Required: LOW | Authentication: NONE |
User Interaction: NONE | Confidentiality: COMPLETE |
Scope: UNCHANGED | Integrity: NONE |
Confidentiality: HIGH | Availability: NONE |
Integrity: NONE | |
Availability: NONE | |
| |