A CWE-285 Improper Authorization vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows improper access to executable code folders.

A CWE-284 Improper Access Control vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place executables in a specific folder and run code whenever RemoteConnect is executed by the user.

A CWE-502 Deserialization of Untrusted Data vulnerability exists in SCADAPack x70 Security Administrator (V1.2.0 and prior) which could allow arbitrary code execution when an attacker builds a custom .SDB file containing a malicious serialized buffer.

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxure�� Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure�� Control Expert software when receiving a specially crafted request over Modbus.

A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxure�� Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxure�� Operator Terminal Expert.

A CWE-284:Improper Access Control vulnerability exists in EcoStruxure�� and SmartStruxure�� Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage.

A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxure�� and SmartStruxure�� Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage.

A CWE-284: Improper Access Control vulnerability exists in EcoStruxure�� and SmartStruxure�� Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level.

A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login.