Matches : 249579 Download | Alert*

The affected product is vulnerable to stored cross-site scripting, which may allow an attacker to remotely execute arbitrary code to gain access to sensitive data on the N-Tron 702-W / 702M12-W (all versions).

Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by opening specially crafted project files that may overflow the heap, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.

The affected product is vulnerable to cross-site request forgery, which may allow an attacker to modify different configurations of a device by luring an authenticated user to click on a crafted link on the N-Tron 702-W / 702M12-W (all versions).

A malicious attacker could exploit the interface of the Fieldcomm Group HART-IP (release 1.0.0.0) by constructing messages with sufficiently large payloads to overflow the internal buffer and crash the device, or obtain control of the device.

A local, authenticated user with shell can obtain the hashed values of login passwords via configd traces. This issue affects all versions of Junos OS Evolved prior to 19.3R1.

The affected product is vulnerable to reflected cross-site scripting, which may allow an attacker to remotely execute arbitrary code and perform actions in the context of an attacked user on the N-Tron 702-W / 702M12-W (all versions).

Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. An out-of-bounds read vulnerability may be exploited by processing specially crafted project files, which may allow an attacker to read information.

In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with li ...

Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause the system to write outside the intended buffer area, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.

In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special elements that could be interpreted as a command when the file is opened by spreadsheet software.