[Forgot Password]
Login  Register Subscribe

24128

 
 

131615

 
 

112965

 
 

909

 
 

88036

 
 

136

 
 
Paid content will be excluded from the download.

Filter
Matches : 112926 Download | Alert*

dotCMS 3.7.0 has XSS reachable from ext/languages_manager/edit_language in portal/layout via the bottom two form fields.

Waves MaxxAudio, as installed on Dell laptops, adds a "WavesSysSvc" Windows service with File Version 1.1.6.0. This service has a vulnerability known as Unquoted Service Path. This could potentially allow an authorized but non-privileged local user to execute arbitrary code with elevated privileges on the system.

** REJECT ** DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was withdrawn by its CNA. Further investigation showed that it was not a security issue. Notes: none.

A kernel pool overflow in the driver hitmanpro37.sys in Sophos SurfRight HitmanPro before 3.7.20 Build 286 (included in the HitmanPro.Alert solution and Sophos Clean) allows local users to crash the OS via a malformed IOCTL call.

A kernel pool overflow in the driver hitmanpro37.sys in Sophos SurfRight HitmanPro before 3.7.20 Build 286 (included in the HitmanPro.Alert solution and Sophos Clean) allows local users to escalate privileges via a malformed IOCTL call.

Subrion CMS 4.0.5.10 has SQL injection in admin/database/ via the query parameter.

An Improper Access Control issue was discovered in LCDS - Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA. The following versions are affected: Versions 4.1 and prior versions released before January 20, 2017. An Improper Access Control vulnerability has been identified, which may allow an authenticated user to modify application files to escalate privileges.

A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to ...

An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The w ...

An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot.


Pages:      Start    9687    9688    9689    9690    9691    9692    9693    9694    9695    9696    9697    9698    9699    9700    ..   11292

© SecPod Technologies