Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.
CVSS Score and Metrics +CVSS Score and Metrics -CVSS V3 Severity: | CVSS V2 Severity: |
CVSS Score : 9.8 | CVSS Score : 7.5 |
Exploit Score: 3.9 | Exploit Score: 10.0 |
Impact Score: 5.9 | Impact Score: 6.4 |
|
CVSS V3 Metrics: | CVSS V2 Metrics: |
Attack Vector: NETWORK | Access Vector: NETWORK |
Attack Complexity: LOW | Access Complexity: LOW |
Privileges Required: NONE | Authentication: NONE |
User Interaction: NONE | Confidentiality: PARTIAL |
Scope: UNCHANGED | Integrity: PARTIAL |
Confidentiality: HIGH | Availability: PARTIAL |
Integrity: HIGH | |